Water treatment
DANETV offers the verification of technologies and products for the treatment of wastewater, drinking water, contaminated groundwater and water for special purposes. DHI performs the verification of technologies and products for water treatment.
Contact
Gerald Heinicke
+45 4516 9268
ghe@dhigroup.com
Ongoing verifications:
UV-disinfection of effluent from fish
farms (aquaculture)
Land-based fish farms are often required to disinfect the intake
water to the farm as well as their effluent. Disinfection by UV
light is among the most suitable and economic technologies for this
purpose. The UV disinfection system MR4-320 SS ACN by Ultraaqua A/S
will be tested at a fish farm and verified in accordance with
regulations formulated by the Norwegian Veterinary Institute.
Cleaning of oil-contaminated wastewater
in root zone system
Onshore oil extraction in remote areas are in the
need of low technology cleaning methods for treatment of the
oil-contaminated water retrieved together with the oil from the
formation. The treatment can take place in a root zone system.
Transform af 1994 is therefore at the moment having the oil-removal
effect of there root zone system verified.
Completed verifications:
Verification of small wastewater
treatment plants for holiday cottages
BioKube sells small treatment plants to treat wastewater at
individual properties in the open countryside. BioKube has developed
a technology which ensures that the plant also work after a period
without inlet water from the house. One claim is that the treatment
plant is able to treat incoming water from the house immediately
after a period without incoming water. BioKube has also developed an
energy saving electronic control system for the management of the
treatment plant; this makes it possible close down the unit part
time. The savings in power consumption is at least 50%, when the
plant is not in use. The verification documents are published on
EU ETV's website.
Treatment of water in dental chairs to
prevent biofilm
By use of electrolysis chlorine generation BacTerminator®
Dental from Adept Water Technologies disinfects water entering the
dental unit water line and prevents formation of biofilm. This
ensures that patients and dental staff are not exposed to bacteria and especially Legionella. The verification
was
performed as a joint verification between the EU ETV
programme and the Chinese ETV programme.
Verification Report and
Verification Statement
Flow regulator
Mosbaek
is producing
flow regulators to be
installed in the
sewage systems. By using
flow regulators flooding can be
alleviated in the piping
system.
Extreme
rains
often lasts
only a short
and
a
good solution
is to alleviate
the excess water
in appropriate
parts of the
sewage system.
Mosbaek
is currently having
their
centrifugal
flow regulator CEV
verified.
Verification Report and
Verification Statement.
Reduction of arsenic in drinking water
By means of an iron generator developed by MicroDrop ApS drinking
water with elevated concentrations of arsenic can be treated. The
system includes an iron generator, an aerator, sand filters and a
tank for collection and removal of sludge. In the iron generator
iron is added to the water as Fe (II). The water is pumped through
the aerator, where iron(II) is oxidized to iron(III). Iron forms
poorly soluble hydroxides which adsorb arsenic. In the sand filter
poorly soluble hydroxides and adsorbed arsenic compounds are
removed. The plant was planned tested for reducing arsenic in drinking
water.
Verification Protocol and
Test Plan.
Treatment of water for reuse
The verification concerns filtration technology equipped with a silicon carbide membrane. The technology
was tested for treatment of re-circulated water in swimming pools and the technology works as an alternative to sand filter. The technology
was verified for CoMeTas A/S.
Verification
Statement,
Verification Report
and
Test
Report.
Drinking water from surface water
Coagulation with direct filtration technology for the production of drinking water from surface water sources
was verified for Ingenjörsfirma Ros AB, Sweden. The verification covers the removal of natural organic matter, particles and microorganisms.
Verification Statement,
Verification report and
Test report.